All Categories
Online UPS

Home /  Products /  UPS /  Online UPS

C1KVA-3KVA

  1. Real-time Dual Conversion
  2. Microprocessor control ensures high reliability
  3. Power factor up to 0.9
  4. Wide input voltage range(110V-300V)
  5. Output sine wave,compatible with generators
  6. Optional SNMP card for independent or seamless monitoring with RS232
  • Overview
  • Related Products

Widely used in network management centers and computers, banks, securities, taxation, communications, postal services, radio and television, public security, transportation, electric power, medical, industrial control, national defense and other important data fields.

Products specifications:

Model C1K(S)
Phase Single-phase
Capacity 1KVA/900W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range 115~300VAC
Input frequency 40Hz~70Hz
Power factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
AC voltage regulation ±1%
Frequency (synchronous range) 47-53Hz/57-63Hz
Frequency range (Battery Mode) 50Hz±0.25Hz/60Hz±0.3Hz
Current crest ratio 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave
Efficiencies
Mains mode 93%
Battery mode 91%
Battery
Stardard UPS
Battery model 12V/7AH
battery amount 2
Charging time 6 hours to be 90% full capacity
Max charging current 1A
Charging voltage 27.4VDC±1%

External battery UPS

Battery model Depends on the applicant
Batteries quantity 3
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 41VDC±1%
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Physical performance
Stardard UPS
Size (MM) 280*148*220
Weight (KG) 8.1

External battery UPS

Size (MM) 280*148*220
Weight (KG) 4.1
Usage environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Products specifications:

Model C2K(S)
Phase Single-phase
Capacity 2KVA/1800W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range 115~300VAC
Input frequency 40Hz~70Hz
Power factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
AC voltage regulation ±1%
Frequency (synchronous range) 47-53Hz/57-63Hz
Frequency range (Battery Mode) 50Hz±0.25Hz/60Hz±0.3Hz
Current crest ratio 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave
Efficiencies
Mains mode 93%
Battery mode 91%
Battery
Stardard UPS
Battery model 12V/7AH
battery amount 4
Charging time 6 hours to be 90% full capacity
Max charging current 1A
Charging voltage 54.7VDC±1%

External battery UPS

Battery model Depends on the applicant
Batteries quantity 6
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 54.7VDC±1%
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Physical performance
Stardard UPS
Size (MM) 395*148*220
Weight (KG) 14.2

External battery UPS

Size (MM) 460*190*330
Weight (KG) 6.2
Usage environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Products specifications:

Model C3K(S)
Phase Single-phase
Capacity 3KVA/2700W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range 115~300VAC
Input frequency 40Hz~70Hz
Power factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
AC voltage regulation ±1%
Frequency (synchronous range) 47-53Hz/57-63Hz
Frequency range (Battery Mode) 50Hz±0.25Hz/60Hz±0.3Hz
Current crest ratio 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave
Efficiencies
Mains mode 95%
Battery mode 92%
Battery
Stardard UPS
Battery model 12V/7AH
battery amount 6
Charging time 6 hours to be 90% full capacity
Max charging current 1A
Charging voltage 82.1VDC±1%

External battery UPS

Battery model Depends on the applicant
Batteries quantity 8
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 109VDC±1%
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Physical performance
Stardard UPS
Size (MM) 425*192*320
Weight (KG) 20.8

External battery UPS

Size (MM) 425*192*320
Weight (KG) 11
Usage environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Quote

Demand type
Name
Country
Company Name
Mobile
Email
Message
0/1000